construction Contact Service email General Contact public Contact Sales travel_explore Contact Partner
construction email public travel_explore
Product filter
Product Filter
Pressure monitor FD

FD
Pressure monitor

Flexible and highly robust pressure monitor for safe and reliable monitoring of pressure limits.


Functionality: Mechanical spring-loaded membrane switching system

  • Excess pressure monitor for gases and excess or reduced pressure monitor for air
  • Suitable for all gases in accordance with DVGW worksheet G 260 and for air
  • Available for increased application requirements in accordance with DIN EN 1854 class “S”
  • Increased media resistance through the use of membranes made of fluorocarbon rubber, materials free of non-ferrous metals
  • Robust die-cast aluminum housing, optionally with housing coating
  • Continuously variable switching pressure adjustment
  • Variable electrical connection variants
  • Local indication when switching pressure is reached
  • Approvals: DVGW, EAC
  • Fastening clips integrated in the pressure monitor
  • Safe and reliable monitoring of pressure limits
  • Reliable and long-lasting operation due to high-quality components 
  • Use in harsh and difficult environments
  • Flexible use thanks to extensive equipment options
  • Straightforward installation and commissioning
  • Combustion technology
  • Ventilation technology
  • Air conditioning
  • Coating systems
  • Technical data
Pressure monitors / pressure switches for gases and air
Operating voltage24 … 250 VAC, 5 … 24 VDC
Switching capacity24 … 250 VAC, 1 A at cos φ = 15 … 24 VDC, 215 … 45 mA
Protection class1
Electrical connectionConnection terminals via cable entry M20 x 1.5
Housing materialDie-cast aluminum
Pressure connectionRp ¼
Ambient temperature−20 … +80 °C
Setting range2 … 10 mbar, 5 … 70 mbar, 10 … 250 mbar
Operating pressureMax. 300 mbar
Test nippleStainless steel Ø 9 mm
Signal lampBasic version: Without
Protection typeIP54
  • Excess and reduced pressure or differential pressure
  • Continuously variable switching pressure adjustment
  • Robust and solid Aluminum housing
  • Increased requirements and media resistance
  • Variable connection plug variants (standard plugs)