Product Filter
Features
- Digital real-time images with a resolution of 1,400 x 1.050 pixels
- High-speed lens with better optical resolution than the camera used
- Wide and flexible angle of view from 30 … 90°
- Can be used at up to 2,000 °C in the combustion chamber
- Can be expanded into a thermography and analysis system with the D-VTA 200 software
Benefits
- Brilliant live images from the combustion chamber around the clock
- Detection of radiation and process fluctuations: The exposure time is not automatic and can be set by remote control, which means that radiation fluctuations in the process or flames are detected immediately
- Wide angle of view into the combustion chamber, as the furnace camera penetrates through the furnace wall into the chamber
- Low maintenance costs: Thanks to the high-temperature lens, a retraction unit is generally not required
- Flexible system: The furnace camera can be expanded into a thermography system with the thermography software D-VTA 200
Applications
- Monitoring of the out burning zone in grate fired furnaces for waste or biomass incineration
- Monitoring of temperature distribution on and above the grate in waste incineration or biomass power plants
- Visualization of combustion in power plant boilers with coal, oil or gas combustion
Technical Data
- Technical data
Video resolution | D-FS 50 ... IP04 ... : 1,280 x 960 pxD-FS 50 ... IP09 ... : 1,400 x 1.050 px |
---|---|
Video signal | Digital, GigE Vision, compatible with D-VT 50 and D-VTA 200 |
Field of view | D-FS 50 VIS90… : 90°, 72°, 54° (diagonal, horizontal, vertical)D-FS 50 VIS60… : 60°, 48°, 36° (diagonal, horizontal, vertical)D-FS 50 VIS30… : 30°, 24°, 18° (diagonal, horizontal, vertical) |
Temperature measurement range | 600 … 2,000 °C using the thermography software D-VTA 200 |
Cooling media and purge air | D-FS 50 … A60 (air-cooled):Connections: 2x G1/2″ external threadPurge air: > 10 Nm3/h at T < 45 °CCooling air: > 30 Nm3/h at T < 45 °C D-FS 50 … W70 (water-cooled):Connections: 3x G1/2″ external threadPurge air: > 10 Nm3/h at T < 45 °CCooling water: > 500 l/h at T < 45 °C and p > 2.5 bar |
Pressure in combustion chamber | -100 … +100 mbar |
Electrical connection | 12 VDC, < 10 VA (via D-SCU) |
Maximum permitted temperature in combustion chamber | 2,000 °C (D-FS 50 … W70-xxxx)1,600 °C (D-FS 50 … A60-xxxx) |
Ambient temperature | -30 … +60 °C -30 … +80 °C (with purge air) |
Temperature monitoring | PT100 at the sensor tip |
Degree of protection | IP66 |
Connections | 1x GigE M121x 4-pin M12 |
Dimensions | d = 60 mm (D-FS 50 … A60)d = 70 mm (D-FS 50 … W70)See drawings for further dimensions |
Weight | 6.4 kg (D-FS 50 … W70-700)4.2 kg (D-FS 50 … A60-700) |
Accessories
- Recommended
- Optional
D-FS NW cable 10GB M12 |
D-FS cable 4-pin M12 |
D-RU | D-SCU |
Flange with protection tube |
Mounting flange |
Air filter system |