CompanyProductsSales&ServiceGuestbookSearch
 
Pilot Burners 
Burners 

 

logo_hegwein_120.gif

Hegwein burners feature the same sturdy, modular design characteristics as the pilot burners. Burners may be equipped with a built-in ignition transformer, or with both flame signal amplifier and ignition transformer. Models are available for either intermittent or continuous operation.

Hegwein also offers a full range of burners, ranging from 120,000 to 6,830,000 BTU. Tube diameters range from 1.97 to 8.66 in.

The chart below shows the major features of our burner lines.

You can also view photos and dimensional drawings of several burner models with the i-buttons at the bottom of this page

The article Useful Information about Ionization Flame Monitoring (Flame Rod) details the operation of the flame rods in Hegwein burners and pilot burners. The Hegwein demo clip shows the operation of our pilot burner demonstration with the ignition and flame monitoring technology used in our burner and igniter lines.

Hegwein Burner Models

Tube Diameter

1.97 in./
50 mm.

1.97 in./
50 mm.

2.76 in./
70 mm.

3.54 in./
90 mm.

5.31 in./
135 mm.

6.30 in./
160 mm.

8.66 in./
220 mm.

Heat Release

120,000 BTU /
35 kW

120,000 BTU /
35 kW

290,000 BTU /
85 kW

685,000 BTU /
200 kW

1,195,000 BTU /
350 kW

2,730,000 BTU /
800 kW

6,830,000 BTU /
2000 kW

Turn-Down Ratio

10 : 1

10 : 1

10 : 1

10 : 1

10 : 1

10 : 1

10 : 1

Quick-Change Design:
fast replacement of gas lance and power head without removing the air and gas entry pipework

 

Yes

Yes

Yes

 

 

 

 

Burner Type

Without Electrical
Components

BGK0

BG0

BG1

BG2

BG3

BG4

BG5

 With built-in
   
 spark
    transformer
Plug and
    Socket   
    connection
220/230 V        or 110/120 V,
   50/60 Hz

BTK0

BT0

BT1

BT2

BT3

BT4

BT5

With built-in  
   spark
   transformer
   and flame
   monitor
For
   
intermittent
   operation
plug and
   socket
   connection
220/230 V
   or 110/120 V,
   50/60 Hz

BAK0

BA0

BA1

BA2

BA3

BA4

BA5

with built-in
  
 spark
Transformer
   and flame
   monitor
For
   continuous
   operation
Plug and
   socket 
   connection
220/230 V or 
   110/120 V,
    50/60 Hz

BDAK0

BDA0

BDA1

BDA2

BDA3

BDA4

BDA5

With built-in
  
 spark
   transformer
   and burner
   control
For
   intermittent
   operation
Plug and
   socket
   connection
220/230 V or
 
 110/120 V,
   50/60 Hz

-

BR0

BR1

BR2
btn_i.gif

BR3
btn_i.gif

BR4
btn_i.gif

BR5

With built-in
  
 spark
   transformer
   and burner
   control
For
   continuous
   operation
Plug and
   socket
   connection
220/230 V or
 
 110/120 V,
   50/60 Hz

-

BD0

BD1

BD2

BD3

BD4

BD5

 
© 2005 DURAG, Inc. All rights reserved